How to Measure Vacuum System Leak Rate: Pressure-Rise Examples, Unit Conversion and Method Selection

Most shops measure a leak the same way: pump to ultimate, close the main valve, watch the gauge. The method is sound; the misreading happens afterwards. A pressure-rise test gives one slope, and that slope contains air entering through a real leak, gas released from internal trapped volumes, permeation through elastomer seals and desorption of water from surfaces. Without separating them, a sound furnace gets condemned and a genuine leak seam gets written off as “outgassing”. The order below is the calculable one: get the leak rate, check what it does to the pressure, then decide when the rise test is no longer enough.

1. Separate hard leaks, virtual leaks and outgassing

After isolation, pressure rises for more than one reason. A hard leak passes outside air through a weld pore, flange face, threaded joint or viewport seal — direction single, rate stable. A virtual leak is gas escaping from a trapped volume inside the chamber (double-wall welds, blind threaded holes, unwelded sandwich layers) — an internal source, not a hole to atmosphere. Outgassing is water and oil film desorbing from surfaces plus permeation through seals.

Read the curve shape, not one number. A hard leak keeps its rate as pressure climbs, so the curve is straight. Outgassing and virtual leaks fall off as pressure rises, so the curve is steep then flat. That is why short tests mislead: in the first ten minutes you are mostly watching desorption, and the leak rate you compute runs an order of magnitude high.

2. Pressure-rise method: one formula, two worked examples

The governing relation is Q = V × Δp / Δt, with V the isolated volume (m³), Δp the pressure rise (Pa) and Δt the holding time (s); Q comes out in Pa·m³/s. Q is a gas quantity, not a pressure, so chambers of different volume can only be compared after conversion.

Example 1 — 1.8 m³ furnace, main valve closed for 1 h. Pressure goes from 15.0 Pa to 18.2 Pa, so Δp = 3.2 Pa, a rise rate of 3.2 Pa/h.

Q = 1.8 × 3.2 / 3600 = 1.6×10⁻³ Pa·m³/s, i.e. 1.6×10⁻² mbar·L/s (1 Pa·m³/s = 10 mbar·L/s).

Heat-treatment shops commonly accept a cold pressure-rise rate around 0.7 Pa/h; at 3.2 Pa/h this furnace is 4.6 times that and deserves attention. The figure tells you how much gas is entering, not where.

Example 2 — same furnace, 30 min only. 1.7 Pa in half an hour scales to 3.4 Pa/h, Q = 1.7×10⁻³ Pa·m³/s. Close, but the instrument error now weighs twice as much: with 0.1 Pa resolution, a 1 h test carries about 3% uncertainty, a 30 min test about 6%. That is why the same system yields two different numbers on two visits.

UnitConversion to Pa·m³/s
Pa·m³/s (SI)1
mbar·L/s10
Torr·L/s7.5
atm·cm³/s (scc/s)0.101

3. What the leak does to pressure: P = Q / S_eff

A leak rate alone does not decide whether a system works; it has to be read against effective pumping speed: P = Q / S_eff.

With Q = 1.6×10⁻³ Pa·m³/s:

  • On a DPL-V630B at 640 m³/h = 0.178 m³/s: ΔP ≈ 9×10⁻³ Pa (9×10⁻⁵ mbar), 0.1% of its 8×10⁻² mbar ultimate — negligible.
  • On a DPL-2V275 at 255 m³/h = 0.071 m³/s: ΔP ≈ 2.3×10⁻² Pa (2.3×10⁻⁴ mbar) — 46% of its 5×10⁻⁴ mbar ultimate.

Same leak, two orders of magnitude apart in consequence. At low pressure the actual speed is below the nominal figure, so the real penalty is worse. Set the target pressure first, then take the pump’s speed at that pressure to derive the allowable leak; never use the ultimate pressure alone as the pass criterion.

4. When the rise test is not enough: sectional isolation and helium testing

The rise test cannot locate a leak, and it cannot see leaks around 10⁻⁶ mbar·L/s — at that size the gauge simply does not move. Isolate in sections first: close the valve between chamber and pumping line, measure the rise of each section, compute Q for each (multiplying by its own volume) and compare. Pumping lines, bellows, quick-couplings and valve packing account for a fair share of field leaks.

Helium mass-spectrometer testing comes second. Method selection and grading can follow ISO 20485:2017, testing practice ASTM E499, and the instrument itself must be calibrated against a calibrated leak as described in ISO 3530:2019. Standards frame the method; the actual acceptance value is agreed in the specification, and it differs by orders of magnitude between a roughing furnace and a semiconductor chamber.

5. Four things that skew the reading

  1. Temperature not settled. Δp = p × ΔT / T: at 100 Pa and 293 K, a 1 K wall rise fakes about 0.34 Pa; at 1000 Pa it fakes 3.4 Pa.
  2. Oil vapour backstreaming after shutdown reads as a rise — confirm the pump side is isolated and the ballast/vent sequence is right.
  3. Changing gauge range between readings; keep one gauge and one range for the whole test.
  4. Virtual leak taken for a hard leak: welding over it changes nothing, because the gas source is inside a trapped layer. Extend the hold and read the later slope.

Write four items into the acceptance clause: which section is tested and its volume, how long it is held (1 h or more, with temperature stability stated), which unit is used, and the pass value. Miss any one and the argument starts at handover.

One reminder: pumping speed and leak behaviour both depend on mains frequency. In 60 Hz regions, size against the actual frequency before ordering — some models are not suited to 60 Hz supplies, so confirm the motor and speed configuration with us first.

Frequently asked questions

How long should a pressure-rise test run?
One hour after temperature stabilisation is the practical minimum. A 1.8 m³ chamber rising 3.2 Pa in an hour gives Q = 1.6×10⁻³ Pa·m³/s; a 30-minute test doubles the weight of gauge resolution error.
How do I convert a pressure-rise rate into a leak rate?
Use Q = V × Δp / Δt. For 1.8 m³ at 3.2 Pa/h: Q = 1.8 × 3.2 / 3600 = 1.6×10⁻³ Pa·m³/s, equal to 1.6×10⁻² mbar·L/s, since 1 Pa·m³/s = 10 mbar·L/s.
Why does the same leak matter for a two-stage pump but not a big single-stage one?
Because P = Q / S_eff. At Q = 1.6×10⁻³ Pa·m³/s, the DPL-V630B at 640 m³/h adds only 9×10⁻⁵ mbar; the DPL-2V275 at 255 m³/h adds 2.3×10⁻⁴ mbar, 46% of its 5×10⁻⁴ mbar ultimate.
When is a helium leak test required instead?
When the leak must be located, or when the target is below 10⁻³ mbar and the rise test shows nothing. Follow ISO 20485:2017 for method, ASTM E499 for practice, and calibrate the detector per ISO 3530:2019.

Need a model recommendation or a quote?

Tell us the required pumping speed, ultimate pressure, gas handled, dust and corrosion conditions, duty cycle and power supply; we will size the model for your process.

Contact us