Why PVD Coating Lines Suffer from Pumping Speed Fluctuation: Conductance, Leak Rate and Pump-Down Time

Same chamber, same batch of parts: the morning shift pumps down from atmosphere to the handover pressure in six minutes and the afternoon run takes eight and a half. Nothing was swapped, no alarm, the gauge is fine. Pumping speed fluctuation on a PVD coating line is rarely a failed pump; it is the middle section changing — pipe conductance, leak and outgassing, and the time difference those two produce once you put them into the pump-down equation.

Start with what the process needs. The magnetron sputtering tool published by Tsinghua University’s nano-centre lists an ultimate vacuum of 7.0×10⁻⁵ Pa, a process pressure of 0.1–10 Pa, and Ar / O₂ / N₂ as working gases. Those two bands are two different jobs: the roughing stage moves a large gas load out of atmosphere, the process stage holds pressure at one point between 0.1 and 10 Pa. If the rough-vacuum stage drifts, no throttle-valve adjustment downstream can make up for it.

1. First account: how much of the speed the pipe eats

The speed on the nameplate is measured at the pump inlet flange. Gas travelling from the chamber to that flange passes through piping that resists flow, described by conductance C (L/s). Pump speed S and pipe conductance add in series:

1/S_eff = 1/S + 1/C

Common engineering estimates for a round pipe (air at 20 °C, d and L in cm, C in L/s):

  • Molecular flow: C ≈ 12.1 × d³ / L
  • Viscous flow: C ≈ 1.4 × d⁴ × P̄ / L (P̄ = mean pressure in the pipe, Pa)

The regime follows the Knudsen number Kn = λ/d; Kn > 1/3 is treated as molecular flow. For air at 20 °C the mean free path is λ ≈ 6.7 mm ÷ p (p in Pa).

Take a DPL-V0202 (200 m³/h, i.e. 55.6 L/s, 5.5 kW, 0.1 mbar with gas ballast closed, G2″ ports) on a 50 mm bore pipe three metres long:

Pipe pressureKnudsen numberRegimePipe conductance CEffective speed at chamberShare of nominal
0.5 mbar (50 Pa)0.003viscous146 L/s40.2 L/s72%
5 Pa0.027transition5.0–14.6 L/s4.6–11.6 L/s8–21%
0.1 Pa1.34molecular5.0 L/s4.6 L/s8%

At half a millibar the same pipe costs 28 percent of the speed. At 0.1 Pa the effective speed is 8 percent of nominal. That is the core of the problem: moving from a 200 m³/h pump to a 300 m³/h DPL-V0302 (7.5 kW) lifts the effective speed at 0.1 Pa from 4.62 to just 4.75 L/s, +2.9 percent, while widening the same pipe from 50 to 80 mm bore takes it from 4.62 to 15.05 L/s, 3.3 times.

Because the pipe clamps the effective speed, anything that changes the pipe changes the speed: a bellows partly collapsed under vacuum, a loaded inlet filter, a gate valve not fully open. None of that shows on a pump nameplate, and all of it rewrites S_eff.

2. Second account: the pressure-rise rate decides whether you reach base pressure

GB/T 32218-2015 (Vacuum technology — Test methods for leak rates of vacuum systems, issued 2015, effective 2017) specifies the static pressure-rise method, which can be run on site: pump the system to a stable pressure, close the valve to isolate the pumps, and record pressure against time. Take two points A(t1, p1) and B(t2, p2) on the linear section with t2 − t1 of at least 300 s, with a temperature correction:

Q = V × (p2/T2 − p1/T1) / (t2 − t1)

With temperature change negligible this reduces to Q = V × Δp / Δt, in Pa·m³/s.

Worked example: a 1.5 m³ chamber valved off at 1 Pa reads 13 Pa ten minutes later. Q = 1.5 × 12 / 600 = 3×10⁻² Pa·m³/s, or 0.3 mbar·L/s — already a large figure.

Compare against an allowance, not a feeling. Allowable leak rate = target base pressure × effective speed of the high-vacuum pump. For a 1×10⁻³ Pa target on a 1000 L/s pump, the allowance is 1×10⁻³ Pa·m³/s. The example above is 30 times that, so the base pressure settles at Q/S = 3×10⁻² Pa, one and a half decades above target.

There is a reading trap: the curve falls steeply then flattens. The early rise is outgassing from walls, parts and seals; only once outgassing saturates and the curve goes straight is the slope the true leak rate. That is why the standard asks for a linear section and a recording span on the order of twelve hours.

3. Third account: put the effective speed into the pump-down time

t = (V / S_eff) × ln[(p1 − pu) / (p2 − pu)], with pu = Q / S_eff as the floor set by leak and outgassing. When pu is far below p2 this reduces to t = (V / S_eff) × ln(p1 / p2).

For a 1.5 m³ chamber from 1013 to 10 mbar, using the conductance at 0.5 mbar (a conservative simplification; the atmospheric end is faster because viscous conductance is much higher):

ConfigurationEffective speedPump-down time
V0202 with 3 m of 50 mm bore40.2 L/s172 s (2.9 min)
V0202 with 3 m of 80 mm bore52.5 L/s132 s (2.2 min)
V0202, 50 mm bore, loaded inlet filter (conductance down to 40 L/s)23.3 L/s297 s (5.0 min)

The spread between a clean and a loaded filter is 125 s per run, which is 63 minutes a day at 30 runs. That is the order of the six-minute versus eight-and-a-half-minute complaint: the pump did not lose 30 percent, the piping lost 40 percent, and pump-down time scales as 1/S.

4. Sizing the pump set so it stays stable

Use V0202 as the single-pump baseline: 200 m³/h, 5.5 kW, 0.1 mbar with ballast closed, G2″ ports — enough for chambers under 0.6 m³ with a relaxed cycle. Above 1 m³, or when 90 seconds to handover pressure is required, add a Roots stage: LC250 (250 m³/h, 2.2 kW, ISO63 in / ISO40 out) or LC500 (500 m³/h, 2.2 kW, ISO100 in / ISO63 out). A Roots pump does not compress gas, it moves it from the low side to the high side; keep the speed ratio between 2 and 4, bring the Roots stage in only after the backing pump has reached 10–30 mbar, and stay off the manufacturer’s maximum differential pressure.

For larger chambers, DPL-V0302 (300 m³/h, 7.5 kW) or DPL-V630B (640 m³/h, 15 kW, DN100 / DN160 inlet) — the DN160 port exists to let the inlet line run large in the molecular-flow range.

One layout point is often missed: put the pump near the chamber and let the exhaust line be the long one. The exhaust works at higher pressure, so its conductance costs far less than the same length on the inlet side. On retrofit projects that change usually pays faster than a bigger pump.

5. Three checks every quarter

First, the pressure-rise baseline: valve off for ten minutes under the same conditions, record Δp, compare with last quarter; a doubling means leak hunting by section. Second, the differential pressure across the inlet filter: rising differential means falling conductance, straight into the first account. Third, piping and valves: bellows collapse, gate-valve travel, seal faces.

For 60 Hz markets, some models are not suited to 60 Hz supplies — confirm motor and speed configuration before ordering. Run the numbers in the site pump-down calculator, see the FAQ for common selection questions, and the coating and surface treatment and chamber roughing pages for related configurations.

Frequently asked questions

How long does a 1.5 m³ chamber take from atmosphere to 10 mbar?
With a DPL-V0202 (200 m³/h, 55.6 L/s) on 3 m of 50 mm bore, effective speed is 40.2 L/s and the time is about 172 s; the same line at 80 mm bore gives 52.5 L/s and about 132 s. That 40 s matters on a tight cycle.
Why does replacing a 200 m³/h pump with a 300 m³/h one barely change the pump-down time?
At 0.1 Pa a 50 mm bore, 3 m line has only 5.0 L/s conductance, clamping effective speed at 4.6 L/s. A DPL-V0302 raises it to 4.75 L/s, +2.9 percent. Going to 80 mm bore reaches 15.05 L/s, 3.3 times.
What pressure-rise rate is acceptable?
There is no single number; back-calculate it. Allowable leak rate = target base pressure × effective speed of the high-vacuum pump. For 1×10⁻³ Pa on a 1000 L/s pump the allowance is 1×10⁻³ Pa·m³/s; a measured 3×10⁻² Pa·m³/s means base pressure stalls at 3×10⁻² Pa.
When should the Roots stage cut in, and what speed ratio?
After the backing pump reaches 10–30 mbar. Keep the speed ratio (Roots speed ÷ backing speed) between 2 and 4; above 4 the differential pressure is too high for anything but short intermittent duty. LC500 against V0202 is about 2.5, a mild combination.

Need a model recommendation or a quote?