Sizing a Pump for a Food Vacuum Packaging Line: Four Parameters, Four Calculations

Pump selection for a food vacuum packaging line usually gets decided by a single number — pumping speed in m³/h. The same 40 m³/h pump feels instant on a 400-series single-chamber machine and becomes the bottleneck on a 600-series double-chamber unit. Put a 100 m³/h pump on a 20 L chamber and you have bought electricity, noise and floor space for nothing. What actually decides the model is four calculable numbers: air to be removed per cycle, target pressure inside the bag, effective pumping speed after line losses, and the leak load of chamber and bag.

1. Air to remove per cycle

Start with volumetric throughput, not with the pump.

A common 600-series double-chamber machine has a chamber of 600 × 550 × 120 mm, i.e. 39.6 L, taken as 40 L. Bags and product occupy 10–15 percent, but for a conservative estimate we keep the full 40 L.

At 600 packs per hour — 10 packs per minute — the two chambers alternate, so each chamber runs 5 cycles per minute:

  • 5 cycles/min × 40 L = 200 L/min = 12 m³/h of atmospheric air

That 12 m³/h is the geometric flow of air moved out. As chamber pressure falls, the volumetric flow entering the pump also falls, so the nominal pumping speed must be several times this figure. A first estimate of 3–5× gives 36–60 m³/h, which lands on DPL-V0040A (40/48 m³/h) or DPL-V0063 (63/75 m³/h).

2. Residual oxygen works out the target pressure

Industry surveys put the typical preset vacuum level of food vacuum packers at 600–1333 Pa, that is 6–13 mbar absolute. The range comes from residual oxygen, not from taste.

If the chamber is evacuated to p and then backfilled with nitrogen to atmospheric before sealing, the fraction of air left in the bag is p/1013, and the oxygen share is 0.21 of that:

Final pressure (mbar abs.)Residual airResulting oxygen
50.49%approx. 0.10%
100.99%approx. 0.21%
504.9%approx. 1.0%

Between 5 and 50 mbar the residual oxygen differs by a factor of ten. That is why meat, fish and ready-meal lines pull down to 5–10 mbar while snack and powder lines stop at tens of mbar.

Going lower buys little. Evacuation does not remove oxygen dissolved in the product tissue or trapped in porous structure. A 2015 review of oxygen absorbers in the Journal of Food Science and Technology states the point plainly: after vacuum or modified-atmosphere packaging the headspace still carries residual oxygen, and further reduction is the job of an absorber rather than another decade of vacuum. Setting the line target at 5–10 mbar and relying on film barrier plus absorber is the cheaper combination.

Once the target is 5 mbar, the pump’s ultimate pressure needs 5–10× headroom, i.e. 0.5–1 mbar or better:

ModelSpeed 50/60 Hz (m³/h)Ultimate (gas ballast closed)Reaches 5 mbar
V0025A20 / 260.5 mbarYes, 10× margin
V0040A40 / 480.1 mbarYes
V006363 / 750.1 mbarYes
V0100100 / 1100.1 mbarYes
DPL-V25L / V40L25 / 30 · 40 / 4890 mbarNo
DPL-ZS150140 / 17560 mbarNo

The last two rows matter. The oil-free rotary vane V25L/V40L and the dry claw ZS150 are not slow pumps, but their ultimate of 90 and 60 mbar respectively rules them out of bag evacuation at 5 mbar. They suit handling, bag opening and forming at 40–90 kPa. A packaging line usually runs both: oil-sealed rotary vane for the bag, oil-free for the gripper.

3. Pump-down time: 40 L chamber to 5 mbar

With 40 L and a 5 mbar target, use t = (V / S) × ln(p1 / p2), with p1 = 1013 mbar, p2 = 5 mbar, ln(1013/5) = 5.31, and nominal speed converted from m³/h by dividing by 3.6.

ModelNominal speed (L/s)Ideal timeWith line and end-of-range losses (×1.4)
V0025A5.5638.2 sapprox. 54 s
V0040A11.119.1 sapprox. 27 s
V006317.512.1 sapprox. 17 s
V010027.87.6 sapprox. 11 s

The 1.4 factor is not arbitrary: near atmosphere the inlet speed is close to nominal, close to ultimate it drops; piping, elbows, inlet filters and valve bore take another share. Use 1.3–1.6, or measure and back-calculate on a tight line. Pipe sizing is covered in piping and valves; the three corrections from atmosphere to 1 mbar are in this article; the calculator is at /calculator/.

Back-calculation is the more useful direction. If the line allows 15 s per cycle, dividing by 1.4 leaves 10.7 s of ideal time, so S = 40 × 5.31 ÷ 10.7 ≈ 19.8 L/s, or 71 m³/h. DPL-V0063 at 63 m³/h falls just short; DPL-V0100 at 100 m³/h has margin. That is why 63 m³/h is the common fit for a 600-series double-chamber machine, and lines running under 15 s move to 100 m³/h.

Check pipe velocity while you are at it. DPL-V0063 pulls 17.5 L/s through a G1 1/4″ inlet; with a G1 1/4″ pipe (about 35 mm bore) the velocity is roughly 18 m/s, inside the 10–20 m/s band used for rough vacuum. Reducing to G3/4″ (19 mm bore) pushes it past 60 m/s, and the pressure drop eats the pumping speed — a bigger pump will not fix that.

4. Leak rate by pressure rise, and where oil stops being acceptable

Parameters one to three assume a sealed chamber. Real chambers leak at the sealing bar, the door gasket, hinges and fittings. The pressure-rise test tells you how much.

Following Leybold’s definition, the leak rate of an isolated volume V that rises by Δp in Δt is q = V × Δp / Δt in mbar·L/s. A 40 L chamber rising 3 mbar in 60 s gives:

  • q = 40 × 3 ÷ 60 = 2.0 mbar·L/s

The acceptance rule is that the leak must not affect the working pressure; a common engineering criterion is q ≤ target pressure × effective speed ÷ 10. At 5 mbar and 17.5 L/s this allows 8.8 mbar·L/s, so 2.0 passes.

Two traps. Measure the baseline with an empty chamber — with bags and moist product inside, the rise includes outgassing and the reading is meaningless. And gasket ageing is gradual: 6–8 mbar·L/s is already near the limit, and a few months later the operator reports “the pump got slow” when the gasket is the cause.

Oil is the last boundary. The pump stands next to the packaging machine, and an oil-sealed rotary vane pump discharges oil mist. It needs an exhaust mist separator with the exhaust routed out of the product area; a clogged element puts oil on the sealing zone and the product, a recurring finding in food hygiene audits. Three calculable criteria for replacing the element are in this article. Going fully oil-free means a dry pump, and dry pumps stop at 60–150 mbar — the table above shows the cost.

5. The four parameters together

ParameterValue on this lineConclusion
Geometric flow600 packs/h × 40 L = 12 m³/h3–5× gives 36–60 m³/h to start
Target pressure5–10 mbar (0.1–0.2% oxygen)Ultimate ≤0.5–1 mbar; oil-free vane and claw drop out
Effective speed15 s cycle back-calculates to 71 m³/hDPL-V0100; DPL-V0063 for a 20 s cycle
Leak ratemeasured 2.0 vs limit 8.8 mbar·L/sIn spec; over limit check the gasket first

For 60 Hz regions, recalculate on 60 Hz speeds: V0025A rises from 20 to 26 m³/h, V0063 from 63 to 75, V0100 from 100 to 110. Some models are not suited to 60 Hz areas — confirm motor and speed configuration with us before ordering.

Of the four parameters only the first comes from the production plan. The other three come from the process and the site. When a selection discussion stalls, it is rarely because the pump is too small — usually the target pressure and the cycle time were never pinned down.

FAQ

  1. Q: How do I size a pump for a food vacuum packaging line? A: Start from geometric flow: packs per minute × chamber volume. 600 packs/h with a 40 L chamber gives 12 m³/h; take 3–5× for a first pick, then back-calculate with t=(V/S)×ln(1013/p). A 20 s cycle fits DPL-V0063, a 15 s cycle fits DPL-V0100.

  2. Q: What residual oxygen comes with evacuating to 5 mbar? A: Evacuate to 5 mbar and backfill with nitrogen to atmospheric: residual air is 5/1013 = 0.49%, so oxygen is about 0.10%. At 10 mbar it is about 0.21%, at 50 mbar about 1.0%. Below that, use an oxygen absorber rather than deeper vacuum.

  3. Q: Can the oil-free DPL-V25L handle bag evacuation? A: No. Its 25/30 m³/h is respectable, but the ultimate of 90 mbar cannot reach 5–10 mbar inside a bag. It suits 40–90 kPa handling and bag-opening stations; bag evacuation needs a single-stage oil-sealed pump such as DPL-V0040A or DPL-V0063.

  4. Q: How do I tell whether the chamber leaks too much? A: Isolate the chamber and measure the pressure rise: q = V × Δp / Δt. A 40 L chamber rising 3 mbar in 60 s gives 2.0 mbar·L/s against an allowance of about 8.8 mbar·L/s at a 5 mbar target. Measure the baseline empty, or outgassing will be counted as a leak.

  5. Q: The pump sits next to the packing machine — what about oil mist? A: An oil-sealed pump needs an exhaust mist separator with the exhaust routed out of the product area. Once the element clogs, oil reaches the sealing zone, which is a common finding in food hygiene audits. A fully oil-free alternative means a dry pump, but DPL-ZS150 stops at 60 mbar and covers only low-vacuum stations.

Need a model recommendation or a quote?

Tell us the required pumping speed, ultimate pressure, gas handled, dust and corrosion conditions, duty cycle and power supply; we will size the model for your process.